• Apply for Loan on Solar System

  • Use WELCOME Coupon Code

  • free shipping orders from all item

Cellcronic Falcon 6G Plus 5.5KW-48v Hybrid Inverter

102999 Rs.105000
1.

Pure sine wave output 5500 Watt. Can handle Two 1.5 Ton Air-conditions with rest home load.

2.

6000W Wide MPPT (120~450vdc) charge controller.

3.

Self-consumption and Feed-in to the grid.

4.

Support Lithium and Lead Acid batteries. Special CAN port for a Lithium battery.
Work without the battery in grid presence.

5.

User-adjustable charging current and voltage.

6.

Monitoring software for real-time.

7.

Parallel operation of up to 9 units.

8.

Work with or without a net meter facility. CT port for Zero Export facility.

9.

Programmable multiple operation modes.

10.

Grid-tie, off-grid, and grid-tie with backup.

11.

2 year warranty.

Size:
Warranty: 2 Years
Quantity:

Annual Maintenance Contract

24 Hour Services

Quality Products

Free Shipping Across India

More details

  • Falcon 6G Plus Hybrid Inverter with Energy Storage Selection Guide 

    MODEL Falcon 6G Plus 5.5KW 
    Phase 1-phase in / 1-phase out
    Maximum PV Input Power 6000W 
    Rated Output Power 5500W 
    Maximum Charging Power 5500W 
    GRID-TIE OPERATION
    PV INPUT (DC)
    Nominal DC Voltage / Maximum DC Voltage 360 VDC / 450 VDC 
    Start-up Voltage / Initial Feeding Voltage 120VDC / 150 VDC 
    MPP Voltage Range 120 VDC ~ 430 VDC 
    Number of MPP Trackers / Maximum Input Current 1 / 20A 
    GRID OUTPUT (AC)
    Nominal Output Voltage 220/230/240 VAC
    Output Voltage Range 184 – 264.5 VAC or 195.5 – 253 VAC (Selectable)
    Nominal Output Current 24A 
    Power Factor > 0.99
    EFFICIENCY
    Maximum Conversion Efficiency (DC/AC) 95%
    OFF-GRID OPERATION
    AC INPUT
    AC Start-up Voltage / Auto Restart Voltage 120 – 140 VAC / 180 VAC
    Acceptable Input Voltage Range 120 – 280 VAC or 170 – 280 VAC
    Frequency Range 50 Hz/60 Hz (Auto sensing)
    Maximum AC Input Current 40 A 
    PV INPUT (DC)
    Maximum DC Voltage 450 VDC 
    MPP Voltage Range 120 VDC ~ 430 VDC 
    Number of MPP Trackers / Maximum Input Current 1 / 20A 
    BATTERY MODE OUTPUT (AC)
    Nominal Output Voltage 220/230/240 VAC
    Output Waveform Pure sine wave
    Efficiency (DC to AC) 94% 
    HYBRID OPERATION
    PV INPUT (DC)
    Nominal DC Voltage / Maximum DC Voltage 360 VDC / 450 VDC 
    Start-up Voltage / Initial Feeding Voltage 120VDC / 150 VDC 
    MPP Voltage Range 120 VDC ~ 430 VDC 
    Number of MPP Trackers / Maximum Input Current 1 / 20A 
    GRID OUTPUT (AC)
    Nominal Output Voltage 220/230/240 VAC
    Output Voltage Range 184 – 264.5 VAC or 195.5 – 253 VAC (Selectable)
    Nominal Output Current 24A 
    AC INPUT
    AC Start-up Voltage / Auto Restart Voltage 120 – 140 VAC / 180 VAC
    Acceptable Input Voltage Range 90 – 280 VAC or 170 – 280 VAC
    Maximum AC Input Current 40 A 
    BATTERY MODE OUTPUT (AC)
    Nominal Output Voltage 220/230/240 VAC
    Efficiency (DC to AC) 95% 
    BATTERY & CHARGER
    Nominal DC Voltage 48 VDC
    Maximum Solar Charging Current 100 A 
    Maximum AC Charging Current 100 A 
    Battery TypeLithium / Lead Acid
    GENERAL
    PHYSICAL
    Dimension, D x W x H (mm) 140 x 365 x 468
    Net Weight (kgs) 12 
    INTERACE
    Parallel Function Yes, 9 units
    Communication Port USB, CAN, RS-232, Dry Contact and WiFi
    ENVIRONMENT
    Humidity 0 ~ 90% RH (No condensing)
    Operating Temperature -10°C to 50°C